Quick answer: Buy Gilbert plugs that match your wire type. SPT-1 plugs fit SPT-1 wire and SPT-2 plugs fit SPT-2 wire, because the insulation thickness differs. For C9 LED roofline work on SPT-1 socket wire, stock SPT-1 male and female plugs in the same color as your wire, starting with packs of 50.
Gilbert plugs are the slide-on plugs that turn bulk wire into custom cords and custom light runs. Buy the wrong ones and they will not seat on your wire. This guide covers which Gilbert plugs to buy, male and female, for SPT-1 and SPT-2 wire.
I ran 4 install crews and built a $1M+ install business on custom-cut runs. Plugs were a line on every supply order we placed. Here is how I would buy them today.
In the video above, you can see the Gilbert One Plug, the inline connector that joins two sections of zip cord. This post covers the full plug lineup around it. Every option sits in the plugs and connectors collection, and the wire they fit is in the SPT-1 and SPT-2 wire collection.
What are Gilbert plugs?
Gilbert plugs are slide-on plugs made for SPT zip cord and socket wire. You do not strip the wire. You lay the cut end in the plug, slide the cover on, and metal contacts pierce the insulation to reach the copper. Installers also call them vampire plugs or zip plugs.
That design is why pros use them. You can cut wire to the exact length a house needs and put an end on it in the shop or on the lawn. No wire strippers. No screw terminals.
Contractors typically make their own custom-length extension cords from SPT-1 wire plus Gilbert plugs. The result is a clean install with no extra cord coiled in the flower bed. The extension cords that ship in a kit work fine as backups.
Which Gilbert plugs should you buy for SPT-1 vs SPT-2 wire?
Buy the plug that matches the wire. SPT-1 plugs fit SPT-1 wire. SPT-2 plugs fit SPT-2 wire. Both wires are 18 gauge, but the insulation thickness differs, so the plugs are not interchangeable. For C9 LED roofline work on SPT-1 socket wire, you need SPT-1 male and female plugs.
| Wire type | Gauge | Insulation | Amp rating | Plug to buy |
|---|---|---|---|---|
| SPT-1 | 18 gauge | 0.030 inch | 7 amps | SPT-1 Gilbert plugs |
| SPT-2 | 18 gauge | 0.045 inch | 10 amps | SPT-2 Gilbert plugs |
SPT-1 is the standard socket wire for C9 LED roofline runs. Retrofit C9 LED bulbs draw under 1 watt each, so the load is light. SPT-1 is also the wire contractors build their custom cords from.
SPT-2 has heavier insulation. Crews choose it for incandescent bulbs or long, high-load runs. If you run SPT-2 anywhere on a job, that part of the job needs SPT-2 plugs.
The rule: read the wire type on the spool before you order plugs. The plug type must match the wire type every time.
What is the difference between male and female Gilbert plugs?
A male Gilbert plug has prongs and goes on the supply end of the wire, the end that plugs into the outlet, timer, or cord feeding it. A female Gilbert plug has slots and goes on the far end, where the next cord or light run plugs in. A custom extension cord needs one of each.
Think of power flowing one way. It leaves the outlet, enters your wire through the male plug, and leaves through the female plug. If nothing plugs in after a light run, that run needs a male plug on the feed end and a safe, closed far end.
Female plugs come two ways at Christmas Lights HQ: with a knockout tab or without. Check the product listing for the style that fits how you build your lines. Male and female plugs both come in SPT-1 and SPT-2 versions.
How do the Gilbert plug options compare?
There are three plug styles to know: male, female, and the inline One Plug. Each one comes in an SPT-1 version and an SPT-2 version. The table below shows where each plug goes and what it is best for, so you can match your order to the wire on your truck.
| Plug | Fits wire | Where it goes | Best use |
|---|---|---|---|
| Male Gilbert Plug SPT-1 | SPT-1 only | Supply end | Feed end of C9 LED runs and custom cords |
| Female Gilbert Plug SPT-1 | SPT-1 only | Far end | End of a custom cord or a run that feeds another run |
| Gilbert One Plug SPT-1 | SPT-1 only | Inline | Joining two sections of SPT-1 zip cord |
| Male Gilbert Plug SPT-2 | SPT-2 only | Supply end | Feed end of SPT-2 runs and cords |
| Female Gilbert Plug SPT-2 | SPT-2 only | Far end | End of an SPT-2 cord or a run that feeds another run |
| Gilbert One Plug SPT-2 | SPT-2 only | Inline | Joining two sections of SPT-2 zip cord |
Male and female plugs come in black, brown, green, and white. Match the plug color to the wire color. Green plugs on green wire disappear against shrubs and shingles. White plugs on white wire blend into white trim.
How do you install a Gilbert plug on socket wire or zip cord?
Cut the wire clean and square. Do not strip it. Open the plug, lay the cut end flat in the channel, and slide the cover on until it seats. The contacts inside pierce the insulation and touch the copper. Then test the cord before it goes on a house.
- Check that the plug type matches the wire type. SPT-1 plug on SPT-1 wire. SPT-2 plug on SPT-2 wire.
- Cut the wire square with sharp cutters. A ragged cut leaves stray copper at the end.
- Slide the back cover off the plug.
- Lay the wire flat in the channel with the cut end fully inside the plug body.
- Slide the cover back on until it closes all the way.
- Plug it in and test it in the shop, not on the roof.
Train every crew member on this in the shop first. A plug that is not fully closed is a service call waiting to happen. Make the test step a habit, not an option.
What happens if the plug does not match the wire?
A mismatched plug does not fit right, because each plug is built for one insulation thickness. An SPT-1 plug is sized for the thinner 0.030 inch jacket. An SPT-2 plug is sized for the thicker 0.045 inch jacket. Put either one on the wrong wire and you cannot trust the connection.
The thicker SPT-2 wire fights its way into an SPT-1 plug, and the cover may not close. The thinner SPT-1 wire sits loose in an SPT-2 plug. Either way, you have a weak spot in the line.
Weak spots show up as flickering runs, dead sections, and callbacks. The fix is easy. Keep SPT-1 and SPT-2 plugs in separate, labeled bins. Never mix them in one bag on the truck.
How many Gilbert plugs should you stock per job?
Count plugs by counting cuts. Every custom cord takes one male and one female plug. Every cut run of socket wire takes a male plug on the feed end, plus a female plug if another run plugs in after it. Walk the house, count the runs and jumps, then add spares.
Here is what drives the count up on a job:
- Separate roof sections. Each peak, dormer, or garage line that is cut as its own run needs its own plugs.
- Jumps between sections. Each custom cord that carries power from one run to the next needs a male and a female.
- Cords to the outlet or timer. Each one is cut to length and needs both ends.
- Repairs. A damaged plug in the field gets cut off and replaced on the spot.
Christmas Lights HQ sells Gilbert plugs in packs of 50 and cases of 1,000. Packs of 50 fit a new route. Cases make sense once your crews are cutting wire every day. Running out of plugs in the middle of the season stops a crew cold, so order ahead of the rush.
Which Gilbert plugs should you buy first?
Start with SPT-1 male plugs and SPT-1 female plugs in the same color as your socket wire. That covers C9 LED roofline runs and custom cords, which is the core of a seasonal install route. Add SPT-2 plugs only when you buy SPT-2 wire. Buy both wire and plugs together so they match.
If you buy C9 socket wire by the spool, put matching plugs on the same order. SPT-1 spool, SPT-1 plugs. One order, one wire type, no guessing later.
If you are stocking up from zero, look at the Pro Kits. They ship with bulbs, socket wire, shingle tabs, plugs, and extension cords pre-matched to each other. I point contractors to the 2,000 ft Contractor Pack first. The 1,000 ft Starter Pack is the step-down, and it is still the right first order for most new contractors because it covers 5 to 6 homes.
Then add extra packs of male and female plugs on top of the kit. Custom cords eat plugs fast, and spares cost little next to a crew standing around.
What wire is on your truck right now, SPT-1 or SPT-2, and do your plug bins match it?
Ready to stock up for the season?
Frequently asked questions
what are gilbert plugs used for
Gilbert plugs are slide-on plugs that put an end on bulk SPT zip cord or socket wire. Contractors use them to build custom-length extension cords and custom-cut light runs. You do not strip the wire. The contacts in the plug pierce the insulation when you slide the cover on.
can you use spt-1 plugs on spt-2 wire
No. SPT-1 plugs fit SPT-1 wire and SPT-2 plugs fit SPT-2 wire. The insulation on SPT-2 is thicker, 0.045 inch versus 0.030 inch on SPT-1, so each plug is made for one wire type. Match the plug to the wire every time.
do i need male and female gilbert plugs
Yes, for most jobs. The male plug goes on the supply end that plugs into the outlet, timer, or feeding cord. The female plug goes on the far end where the next cord or light run plugs in. A custom extension cord needs one of each.
what color gilbert plugs should i buy
Buy the color that matches your wire. Christmas Lights HQ sells male and female Gilbert plugs in black, brown, green, and white. Green plugs on green wire and white plugs on white wire keep the install clean and hard to see in daylight.
how many gilbert plugs come in a pack
Christmas Lights HQ sells Gilbert plugs in packs of 50 and cases of 1,000. Packs of 50 suit a new route. Cases fit crews that cut custom cords and runs every day of the season.